Mostrar el registro sencillo del ítem

Evaluation of the serum hormonal profile with a progesterone-releasing intravaginal device in sheep

dc.contributor.authorGómez, M. V.
dc.contributor.authorSoto, Ariel Tomás
dc.contributor.authorMigliorisi, A. L.
dc.contributor.authorMestorino, N.
dc.contributor.authorSota, R. L.
dc.date.accessioned2022-07-12T20:58:42Z
dc.date.available2022-07-12T20:58:42Z
dc.date.issued2021-12-01
dc.identifier.citationGómez, M. V., et al., 2021. Perfil sérico hormonal de un dispositivo intravaginal liberador de progesterona en ovejas. Revista Veterinaria. Corrientes: Universidad Nacional del Nordeste. Facultad de Ciencias Veterinarias, vol. 32, no. 2, p. 206-210. ISSN 1669-6840. http://dx.doi.org/10.30972/vet.3225744
dc.identifier.issn1668-4834
dc.identifier.urihttp://repositorio.unne.edu.ar/handle/123456789/49184
dc.description.abstractLos dispositivos intravaginales (DIV) con 300 mg de progesterona (P4) pueden reutilizarse en los protocolos de sincronización en ovinos con una duración de hasta 7 días. La reutilización de DIV con menor concentración hormonal, así como estudios far- maco-cinéticos a través del análisis no compartimental de las concentraciones hormonales luego de la colocación de dispositivos de 1° o 2° uso no han sido descriptos previamente. El objetivo del presente trabajo fue evaluar la utilización y reutilización de dispositivos intrava- ginales con una concentración inicial de 160 mg de P4. Para ello se utilizaron 20 ovejas que conformaron cinco grupos: control (sin DIV), CIDN (DIV 300 mg P4 1° uso), CIDU (DIV 300 mg P4 2° uso), CRON (DIV 160 mg P4 1° uso) y CROU (DIV 300 mg P4 2° uso). Las valoraciones séricas hormonales se realizaron a través de radioinmunoensayo. La concentración máxima y el tiempo medio de residencia fueron similares entre CIDN Y CRON, en cambio CIDU presentó una concentración máxima y un tiempo medio de residencia mayor que CROU. Además, CROU presentó concentraciones séricas sub-luteales a partir de las 48 h de colocado y liberó un 68,5% menos de P4 que CIDU y un 72,5% menos que CRON. En base a los resultados obtenidos, la reutilización de DIV con menor concentración hormonal provocaría niveles sub-luteales que posiblemente afectarían la fertilidad.es
dc.description.abstractIntravaginal devices (IVD) with 300 mg of progesterone (P4) can be reused in sheep synchronization protocols with a duration of up to 7 days. The reuse of IVD with lower hormonal concentration, as well as pharmaco-kinetic studies through non-compartmental analysis of hormonal concentrations after the insertion of 1st or 2nd use devices have not been described previously. The objective of this work was to evaluate the use and reuse of IVD with an initial concentration of 160 mg of P4. For this, 20 sheep were used that made up five groups: control (without DIV), CIDN (IVD 300 mg P4 1st use), CIDU (IVD 300 mg P4 2nd use), CRON (IVD 160 mg P4 1st use), and CROU (IVD 300 mg P4 2nd use). Hormonal serum samples were analyzed by radioimmunoassay. The maximum concentration and the mean residence time were similar between CIDN and CRON, whereas CIDU presented a maximum concentration and a mean residence time greater than CROU. Also, CROU presented sub luteal serum concentrations 48 h after placement and released 68.5% less P4 than CIDU and 72.5% less than CRON. Based on the results obtained, the reuse of IVD with a lower hormonal concentration would cause sub luteal levels that could affect fertility.en
dc.formatapplication/pdf
dc.format.extentp. 206-210
dc.languagespa
dc.publisherUniversidad Nacional del Nordeste. Facultad de Ciencias Veterinariases
dc.publisherRevista Veterinariaes
dc.relation.urihttps://revistas.unne.edu.ar/index.php/vet/article/view/5744
dc.relation.urihttp://dx.doi.org/10.30972/vet.3225744
dc.rightsopenAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/es
dc.sourceRevista Veterinaria, 2021, vol. 32, no. 2, p. 206-210.es
dc.subjectDispositivo intra-vaginales
dc.subjectReusoes
dc.subjectProgesteronaes
dc.subjectOvinoses
dc.subjectIntra-vaginal deviceen
dc.subjectReuseen
dc.subjectProgesteroneen
dc.subjectSheepen
dc.titlePerfil sérico hormonal de un dispositivo intravaginal liberador de progesterona en ovejases
dc.titleEvaluation of the serum hormonal profile with a progesterone-releasing intravaginal device in sheepen
dc.typeArtículo
unne.affiliationFil: Gómez, M. V. Universidad Nacional del Nordeste. Facultad de Ciencias Veterinarias; Argentina.
unne.affiliationFil: Soto, Ariel Tomás. Universidad Nacional del Nordeste. Facultad de Ciencias Veterinarias; Argentina.
unne.affiliationFil: Migliorisi, A. L. Universidad Nacional del Nordeste. Facultad de Ciencias Veterinarias; Argentina.
unne.affiliationFil: Mestorino, N. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina.
unne.affiliationFil: Sota, R. L. Universidad Nacional del Nordeste. Facultad de Ciencias Veterinarias; Argentina.
unne.journal.paisArgentina
unne.journal.ciudadCorrientes
unne.journal.volumevol. 32
unne.journal.numberno. 2
unne.ISSN-e1669-6840


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe comoopenAccess