Mostrar el registro sencillo del ítem

dc.contributor.authorGamboa, Ricardo
dc.contributor.authorMollón, Francisco P.
dc.contributor.authorRíos Méndez, Raúl E.
dc.contributor.authorCayré, Raúl O.
dc.contributor.authorCazzaniga, Mario
dc.contributor.authorArroyo, Graciela M.
dc.contributor.authorGutiérrez, Diego F.
dc.date.accessioned2023-03-17T11:32:40Z
dc.date.available2023-03-17T11:32:40Z
dc.date.issued2008
dc.identifier.citationGamboa, Ricardo, et al, 2008. Fontan pulsátil : oclusión transcatéter de la arteria pulmonary permeable. Seguimiento a mediano plazo. Archivos de Cardiología de México. Ciudad de México: Instituto Nacional de Cardiología Ignacio Chávez, vol. 78, no. 3, p. 293-2998. e-ISSN 1665-1731.es
dc.identifier.issn1405-9940es
dc.identifier.urihttp://repositorio.unne.edu.ar/handle/123456789/51222
dc.description.abstractObjetivo: Reportamos la oclusión percutánea de la arteria pulmonar con flujo residual en pacientes con circuito tipo Fontan. Método: Niños de 9 y 11 años, SaO2 de 88 y 96% respectivamente, uno de ellos con cefalea y clase funcional II, ambos con anastomosis cavopulmonar total con tubo extracardíaco fenestrado y arteria pulmonar permeable (Fontan pulsátil). Un Amplatzer duct-occluder fue implantado en la arteria pulmonar ingresando desde la vena femoral. Control clínico, por imágenes y cateterismo. Resultados: Caso 1: Fenestración permeable, Qp/Qs: 0.7/1. Caso 2: fenestración cerrada, Qp/Qs: 1.3/1. Obtuvimos oclusión inmediata con dispositivos 6/4 y 8/6 mm respectivamente; el trazado de presión cambió la morfología arterial a bifásica; la presión pulmonar descendió 2 mm Hg en el primero, sin modificarse en el segundo; ninguno cambió la SaO2. Tiempo fluoroscópico: 57 y 45 minutos y seguimiento de 2.8 y 2.3 años respectivamente. En el caso 1, cesó la cefalea y al año ocluimos la fenestración con dispositivo Amplatzer septal-occluder, elevando la SaO2 a 96%; no hubo complicaciones ni recanalización de la arteria pulmonar en ningún caso. Conclusiones: El cierre percutáneo de la arteria pulmonar permeable en pacientes con circuito tipo Fontan es un procedimiento factible y efectivo, evitando sobrecarga del ventrículo único.es
dc.description.abstractObjective: We report the percutaneous closure of the pulmonary artery with residual shunt in patients with Fontan type circuit. Method: Patients aged 9 and 11 years, with SaO2 of 88 and 96%, respectively. One of them coursing with headaches and functional class II. Both patients with total cavopulmonary anastomosis and fenestrated extracardiac conduit and permeable pulmonary artery (pulsatile Fontan). An Amplatzer duct-occluder device was implanted in the pulmonary artery entering from the femoral vein. Follow-up by means of clinical examination, imaging, and catetherization was pursued. Results: Case 1, patency fenestration, Qp/Qs: 0.7/1. Case 2, closed fenestration, Qp/Qs; 1.3/1. We obtained immediate occlusion with 6/4 and 8/6 devices, respectively; pressure recordings revealed modification of the arterial morphology to biphasic; pulmonary pressure dropped 2 mm Hg in the first patient, without alteration in the second case; no changes in SaO2 were registered. Time of fluoroscopy was 57 and 45 minutes, respectively. Follow-up was maintained for 2.8 and 2.3 years, respectively. In patient 1, headaches disappeared and the fenestration was occluded with an Amplatzer septal-occluder one year later, raising SaO2 to 96%; no complications occurred nor was recanalization of the pulmonary artery needed in either case. Conclusions: Percutaneous occlusion of patent pulmonary artery in patients with Fontan type circuit is a feasible and effective procedure, and avoids overload of the single ventricle.es
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherInstituto Nacional de Cardiología Ignacio Chávezes
dc.rightsopenAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/es
dc.sourceArchivos de Cardiología de México, 2008, vol. 78, no. 3, p. 293-298.es
dc.subjectCateterismo cardíacoes
dc.subjectFontanes
dc.subjectDispositivoes
dc.subjectFontan-type circuites
dc.subjectOccluder devicees
dc.titleFontan pulsátil : oclusión transcatéter de la arteria pulmonary permeable. Seguimiento a mediano plazoes
dc.typeArtículoes
unne.affiliationFil: Gamboa, Ricardo. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina.es
unne.affiliationFil: Mollón, Francisco P. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina.es
unne.affiliationFil: Ríos Méndez, Raúl E. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina.es
unne.affiliationFil: Cayré, Raúl O. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina.es
unne.affiliationFil: Cazzaniga, Mario. Hospital Montepríncipe. Cardiología Infantil; España.es
unne.affiliationFil: Arroyo, Graciela M. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina.es
unne.affiliationFil: Gutiérrez, Diego F. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina.es
unne.journal.paisMéxicoes
unne.journal.ciudadCiudad de Méxicoes
unne.journal.volume78
unne.journal.number3
unne.ISSN-e1665-1731es


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe comoopenAccess