Mostrar el registro sencillo del ítem

Variation of the intraocular pressure in relation to time of death : contribution to the determination of the true postmortem interval (PMI)

dc.contributor.authorGerometta, Rosana María del Rosario
dc.contributor.authorLarroza, Gerardo Omar
dc.contributor.authorPimpinella, Pascual
dc.contributor.authorGenero, Sebastián
dc.date.accessioned2025-10-13T11:27:10Z
dc.date.available2025-10-13T11:27:10Z
dc.date.issued2019
dc.identifier.citationGerometta, Rosana María del Rosario, et al., 2019. Variación de la presión intraocular en función del tiempo: contribución a la determinación del verdadero intervalo de muerte (VIM). Revista Mexicana de Medicina Forense y Ciencias de la Salud. Boca del Río: Universidad Veracruzana. Instituto de Medicina Forense, vol. 4, no. 1, p. 15-23. ISSN 2448-8011. DOI https://doi.org/10.25009/revmedforense.v4i1es
dc.identifier.issn2448-8011es
dc.identifier.urihttp://repositorio.unne.edu.ar/handle/123456789/58763
dc.description.abstractIntroducción: La determinación del momento del fallecimiento, es un dato de singular importancia en Medicina Legal constituyendo por su complejidad en uno de los problemas que necesita evaluación objetiva en la Patología Forense. Material y Métodos: Se propone en el presente estudio utilizar un modelo vacuno para la toma de la presión intraocular sistematizada pre y post mortem y analizar su evolución en el tiempo como posible método incruento de aproximación al Verdadero Intervalo de Muerte (VIM). Se realizó un estudio prospectivo, observacional, descriptivo con 12 vacas. Para la toma de presión intraocular (PIO) se utilizó el tonómetro manual aplanático (Perkins) calibrado previamente para bovinos. Se midió la PIO a horas establecidas posmortem. Resultados: La PIO promedio a hora 0 en OD fue de 13,48 mm Hg y de 13,59 mm Hg en OS con mínima variación entre los diferentes casos y el promedio del valor final a las 30 hr fue de 6,41 y 6,45 mm Hg en OD y OS respectivamente. Se observa una disminución de la PIO según transcurre el tiempo de muerte, de manera regular, en todos los ojos. Discusión: El hecho de la uniformidad de la disminución de la PIO en función del tiempo permite que una PIO tomada horas después de la muerte se pueda extrapolar al momento de la muerte y poder considerar la toma de la Presión Intraocular como contribución a la aproximación del verdadero intervalo de muerte (VIM).es
dc.description.abstractIntroduction: Postmortem Interval estiamtion is a measure of singular importance in Legal Medicine. Due to its complexity, it needs objective evaluation in Forensic Pathology. Methods: In this study we propose the use of a bovine model to sytematically measure premortem and postmortem Intra-Ocular Pressure (IOP) as well as analyze its evolution with time as a possible non-invasive method to estimate PMI. A prospective, descriptive, observational study was carried out, using 12 cows. For the determination of the IOP, the aplanatic manual Perkins tonometer calibrated for bovines was used. The measurement of the IOP was done at establisehd post-mortem intervals. Results: The mean IOP at hour 0 in OD was 13.48 mm Hg and 13.59 mm Hg in OS with minimal variation between groups; at hour 30 hr, the IOP was 6.41 and 6.45 mm Hg in OD and OS respectively. We observed a decrease of the IOP in al leyes, directly related to the elapsed time of death. Discussion. The uniformity of the IOP estimations in relation to postmortem interval allows us to consider it as a valuable parameter for postmortem interval even several hours after death.es
dc.formatapplication/pdfes
dc.format.extentp. 15-23es
dc.language.isospaes
dc.publisherUniversidad Veracruzana. Instituto de Medicina Forensees
dc.relation.urirevmedforense.uv.mx/index.php/RevINMEFO/indexes
dc.relation.urihttps://doi.org/10.25009/revmedforense.v4i1es
dc.rightsopenAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/es
dc.sourceRevista Mexicana de Medicina Forense y Ciencias de la Salud, 2019, vol. 4, no. 1, p. 15-23.es
dc.subjectIntervalo postmortemes
dc.subjectPresión intraoculares
dc.subjectTonometríaes
dc.subjectPostmortem Intervales
dc.subjectIntraOcular Pressurees
dc.subjectTonometryes
dc.titleVariación de la presión intraocular en función del tiempo : contribución a la determinación del verdadero intervalo de muerte (VIM)es
dc.titleVariation of the intraocular pressure in relation to time of death : contribution to the determination of the true postmortem interval (PMI)es
dc.typeArtículoes
unne.affiliationFil: Gerometta, Rosana María del Rosario. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina.es
unne.affiliationFil: Larroza, Gerardo Omar. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina.es
unne.affiliationFil: Pimpinella, Pascual. Universidad Nacional del Litoral. Facultad de Ciencias Médicas; Argentina.es
unne.affiliationFil: Pimpinella, Pascual. Poder Judicial de la Provincia de Santa Fé; Argentina.es
unne.affiliationFil: Genero, Sebastián. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina.es
unne.journal.paisMexicoes
unne.journal.ciudadBoca del Ríoes
unne.journal.volume4es
unne.journal.number1es


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe comoopenAccess