Mostrar el registro sencillo del ítem
Fontan pulsátil : oclusión transcatéter de la arteria pulmonary permeable. Seguimiento a mediano plazo
dc.contributor.author | Gamboa, Ricardo | |
dc.contributor.author | Mollón, Francisco P. | |
dc.contributor.author | Ríos Méndez, Raúl E. | |
dc.contributor.author | Cayré, Raúl O. | |
dc.contributor.author | Cazzaniga, Mario | |
dc.contributor.author | Arroyo, Graciela M. | |
dc.contributor.author | Gutiérrez, Diego F. | |
dc.date.accessioned | 2023-03-17T11:32:40Z | |
dc.date.available | 2023-03-17T11:32:40Z | |
dc.date.issued | 2008 | |
dc.identifier.citation | Gamboa, Ricardo, et al, 2008. Fontan pulsátil : oclusión transcatéter de la arteria pulmonary permeable. Seguimiento a mediano plazo. Archivos de Cardiología de México. Ciudad de México: Instituto Nacional de Cardiología Ignacio Chávez, vol. 78, no. 3, p. 293-2998. e-ISSN 1665-1731. | es |
dc.identifier.issn | 1405-9940 | es |
dc.identifier.uri | http://repositorio.unne.edu.ar/handle/123456789/51222 | |
dc.description.abstract | Objetivo: Reportamos la oclusión percutánea de la arteria pulmonar con flujo residual en pacientes con circuito tipo Fontan. Método: Niños de 9 y 11 años, SaO2 de 88 y 96% respectivamente, uno de ellos con cefalea y clase funcional II, ambos con anastomosis cavopulmonar total con tubo extracardíaco fenestrado y arteria pulmonar permeable (Fontan pulsátil). Un Amplatzer duct-occluder fue implantado en la arteria pulmonar ingresando desde la vena femoral. Control clínico, por imágenes y cateterismo. Resultados: Caso 1: Fenestración permeable, Qp/Qs: 0.7/1. Caso 2: fenestración cerrada, Qp/Qs: 1.3/1. Obtuvimos oclusión inmediata con dispositivos 6/4 y 8/6 mm respectivamente; el trazado de presión cambió la morfología arterial a bifásica; la presión pulmonar descendió 2 mm Hg en el primero, sin modificarse en el segundo; ninguno cambió la SaO2. Tiempo fluoroscópico: 57 y 45 minutos y seguimiento de 2.8 y 2.3 años respectivamente. En el caso 1, cesó la cefalea y al año ocluimos la fenestración con dispositivo Amplatzer septal-occluder, elevando la SaO2 a 96%; no hubo complicaciones ni recanalización de la arteria pulmonar en ningún caso. Conclusiones: El cierre percutáneo de la arteria pulmonar permeable en pacientes con circuito tipo Fontan es un procedimiento factible y efectivo, evitando sobrecarga del ventrículo único. | es |
dc.description.abstract | Objective: We report the percutaneous closure of the pulmonary artery with residual shunt in patients with Fontan type circuit. Method: Patients aged 9 and 11 years, with SaO2 of 88 and 96%, respectively. One of them coursing with headaches and functional class II. Both patients with total cavopulmonary anastomosis and fenestrated extracardiac conduit and permeable pulmonary artery (pulsatile Fontan). An Amplatzer duct-occluder device was implanted in the pulmonary artery entering from the femoral vein. Follow-up by means of clinical examination, imaging, and catetherization was pursued. Results: Case 1, patency fenestration, Qp/Qs: 0.7/1. Case 2, closed fenestration, Qp/Qs; 1.3/1. We obtained immediate occlusion with 6/4 and 8/6 devices, respectively; pressure recordings revealed modification of the arterial morphology to biphasic; pulmonary pressure dropped 2 mm Hg in the first patient, without alteration in the second case; no changes in SaO2 were registered. Time of fluoroscopy was 57 and 45 minutes, respectively. Follow-up was maintained for 2.8 and 2.3 years, respectively. In patient 1, headaches disappeared and the fenestration was occluded with an Amplatzer septal-occluder one year later, raising SaO2 to 96%; no complications occurred nor was recanalization of the pulmonary artery needed in either case. Conclusions: Percutaneous occlusion of patent pulmonary artery in patients with Fontan type circuit is a feasible and effective procedure, and avoids overload of the single ventricle. | es |
dc.format | application/pdf | es |
dc.language.iso | spa | es |
dc.publisher | Instituto Nacional de Cardiología Ignacio Chávez | es |
dc.rights | openAccess | es |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/2.5/ar/ | es |
dc.source | Archivos de Cardiología de México, 2008, vol. 78, no. 3, p. 293-298. | es |
dc.subject | Cateterismo cardíaco | es |
dc.subject | Fontan | es |
dc.subject | Dispositivo | es |
dc.subject | Fontan-type circuit | es |
dc.subject | Occluder device | es |
dc.title | Fontan pulsátil : oclusión transcatéter de la arteria pulmonary permeable. Seguimiento a mediano plazo | es |
dc.type | Artículo | es |
unne.affiliation | Fil: Gamboa, Ricardo. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina. | es |
unne.affiliation | Fil: Mollón, Francisco P. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina. | es |
unne.affiliation | Fil: Ríos Méndez, Raúl E. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina. | es |
unne.affiliation | Fil: Cayré, Raúl O. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina. | es |
unne.affiliation | Fil: Cazzaniga, Mario. Hospital Montepríncipe. Cardiología Infantil; España. | es |
unne.affiliation | Fil: Arroyo, Graciela M. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina. | es |
unne.affiliation | Fil: Gutiérrez, Diego F. Fundación Favaloro. Instituto de Cardiología y Cirugía Cardiovascular; Argentina. | es |
unne.journal.pais | México | es |
unne.journal.ciudad | Ciudad de México | es |
unne.journal.volume | 78 | |
unne.journal.number | 3 | |
unne.ISSN-e | 1665-1731 | es |
Ficheros en el ítem
Este ítem aparece en la(s) siguiente(s) colección(ones)
-
Artículos de revista [162]