Mostrar el registro sencillo del ítem

Serum creatinine. From clinical practice to epidemiology through determination standars and quality control across clinical laboratories

dc.contributor.authorCusumano, Ana María
dc.contributor.authorVelasco, Gustavo Adolfo
dc.contributor.authorBianchi, María Eugenia Victoria
dc.contributor.authorTorres, Candela
dc.contributor.authorCeci, Romina
dc.contributor.authorMazziotta, Daniel
dc.contributor.authorInserra, Felipe
dc.date.accessioned2021-08-11T13:51:12Z
dc.date.available2021-08-11T13:51:12Z
dc.date.issued2016-09-01
dc.identifier.citationCusumano, Ana Maria, et al., 2016. La creatinina sérica. Desde la clínica a la epidemiología, a través de la estandarización de su determinación y el contro de los laboratorios clínicos. Revista de Nefrología, Diálisis y Trasplante. Ciudad Autónoma de Buenos Aires: Asociación Regional de Diálisis y Trasplantes Renales de Capital Federal y Provincia de Buenos Aires. Asociación Nefrológica de Buenos Aires, vol. 3, no. 36, p. 187-196. ISSN 2346-8548.es
dc.identifier.issn0326-3428es
dc.identifier.urihttp://repositorio.unne.edu.ar/handle/123456789/28367
dc.description.abstractEl presente artículo intentará demostrar por qué es necesario mejorar el control de calidad de los laboratorios clínicos y avanzar hacia la estandarización de la creatininemia para contribuir a mejorar el diagnóstico clínico y epidemiológico de la Enfermedad Renal Crónica especialmente en América Latina. El rol del laboratorio de análisis clínico es brindar información útil, confiable y reproducible para la práctica clínica de la medicina, cualquiera sea la metodología empleada y el laboratorio interviniente. Para ello se implementó calidad para mejorar los errores sistemático y aleatorio en las determinaciones de los laboratorios clínicos. Los programas de estandarización se ponen en marcha en el año 2006. Por otra parte se fue incorporando la creatinina sérica y el clearance de creatinina a la clínica, hasta arribarse a un hito histórico que fue la determinación de la Tasa Filtrado Glomerular estimada (TFGe) a partir de fórmulas (MDRD y CKD-EPI). La necesidad de la estandarización de la determinación de la creatinina fue establecida en la Guía 4, KDOQUI en el año 2002. Respecto a la determinación de la creatinina sérica para la estimación del TFGe, un largo camino se ha recorrido desde la identificación del concepto de clearance, su aplicación a la determinación de la función renal, su utilización en la clínica para el diagnóstico, la progresión y el pronóstico, la identificación de la misma como un indicador epidemiológico a la hora de establecer riesgo poblacional. En ese marco, se manifiesta la necesidad de promover su estandarización.es
dc.description.abstractThis article attempts to show why it is necessary to improve quality control of clinical laboratories and move toward standardization of serum creatinine to help improve clinical and epidemiological diagnosis of chronic kidney disease especially in Latin America. The role of clinical laboratory is to provide useful, reliable and reproducible information to be used in clinical practice, regardless of the methodology used and the intervening laboratory. For this, quality was implemented to improve the systematic and random errors in the determinations of clinical laboratories. Standardization programs are launched in 2006.Moreover serum creatinine and creatinine clearance joined the clinic, to be arrived at a milestone that was the determination of the estimated Glomerular Filtration Rate (eGFR) from formulas (MDRD and CKD-EPI). The need for standardization of the determination of creatinine was established in the Guide 4 KDOQUI in 2002. Regarding the determination of serum creatinine for estimating eGFR, a long way has come: from identification of the concept of clearance, its application to the determination of renal function, its use in the clinic for diagnosis, progression and prognosis, identifying it as an epidemiological indicator in population risk setting. In this context the need for standardization is established.es
dc.formatapplication/pdfes
dc.language.isospaes
dc.publisherAsociación Regional de Diálisis y Trasplantes Renales de Capital Federal y Provincia de Buenos Aires. Asociación Nefrológica de Buenos Aireses
dc.rightsopenAccesses
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/2.5/ar/es
dc.sourceRevista de Nefrología, Diálisis y Trasplante, 2016, vol. 36, no. 3, p. 187-196.es
dc.subjectTasa de filtración glomerulares
dc.subjectEstandarización de creatininaes
dc.subjectGlomerular filtration ratees
dc.subjectSerum creatinine standardizationes
dc.titleLa creatinina sérica. Desde la clínica a la epidemiología, a través de la estandarización de su determinación y el control de los laboratorios clínicoses
dc.titleSerum creatinine. From clinical practice to epidemiology through determination standars and quality control across clinical laboratorieses
dc.typeArtículoes
unne.affiliationFil: Cusumano, Ana María. Centro de Educación Médica e Investigaciones Clínicas; Argentina.es
unne.affiliationFil: Velasco, Gustavo Adolfo. Fundación Renal de Nordeste Argentino; Argentina.es
unne.affiliationFil: Bianchi, María Eugenia Victoria. Hospital “Dr. Julio C. Perrando”. Laboratorio de Análisis Clínicos; Argentina.es
unne.affiliationFil: Torres, Candela. Universidad Nacional del Nordeste. Facultad de Medicina; Argentina.es
unne.affiliationFil: Ceci, Romina. Fundación Bioquímica Argentina. Laboratorio de Referencia y Estandarización en Química Clínica; Argentina.es
unne.affiliationFil: Mazziotta, Daniel. Fundación Bioquímica Argentina. Laboratorio de Referencia y Estandarización en Química Clínica; Argentina.es
unne.affiliationFil: Inserra, Felipe. Hospital Universitario Austral; Argentina.es
unne.journal.paisArgentinaes
unne.journal.ciudadCiudad Autónoma de Buenos Aireses
unne.ISSN-e2346-8548es


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

openAccess
Excepto si se señala otra cosa, la licencia del ítem se describe comoopenAccess