Resumen
En este trabajo se presentan los resultados obtenidos en estudios realizados en el Túnel de Viento de la UNNE, sobre el modelo a escala 1/400 de un edificio de altura superior a 200 m, actualmente en construcción en Brasil. Se obtuvieron los valores medios, de pico máximo, mínimo y rms de los coeficientes de presión local. Una serie de consideraciones referidas a la aplicación del método de aproximación de valores extremos es realizada de forma complementaria. Los ensayos fueron realizados utilizando dos simulaciones de viento natural de espesor total, con valores diferentes del exponente de la ley potencial de velocidades. En el modelo a escala del edificio, se reprodujeron todos los detalles de relevancia aerodinámica. Las presiones fluctuantes locales en 511 puntos de la torre fueron medidas para 24 direcciones de viento incidente, considerando el efecto de vecindad por el entorno edilicio y topográfico.
In this work results of wind tunnel studies performed over a 1/400 scale model of a high-rise building are presented. This building is higher than 200 m and it is nowadays being built in Brazil. Local mean, maximum, minimum and rms pressure coefficients are obtained. Some considerations referred to the extreme values approximation are realized. A full depth natural wind simulation was employed in the experiments. Two different mean velocity profiles were used according to the incident wind direction. Aerodynamic details were reproduced in the building model. Fluctuating local pressures in 511 tower points for 24 wind directions were measured and the effects of vicinity were considered.
In this work results of wind tunnel studies performed over a 1/400 scale model of a high-rise building are presented. This building is higher than 200 m and it is nowadays being built in Brazil. Local mean, maximum, minimum and rms pressure coefficients are obtained. Some considerations referred to the extreme values approximation are realized. A full depth natural wind simulation was employed in the experiments. Two different mean velocity profiles were used according to the incident wind direction. Aerodynamic details were reproduced in the building model. Fluctuating local pressures in 511 tower points for 24 wind directions were measured and the effects of vicinity were considered.
Descripción
Citación
Wittwer, Adrián Roberto, et al., 2014. Análisis experimental de cargas de viento localizadas en un edificio de gran altura. En: XXXVI Jornadas Sudamericanas de Ingeniería Estructural. Montevideo: Asociación Sudamericana de Ingeniería Estructural, p. 1-11.
Colecciones
Aprobación
Revisión
Complementado por
Referenciado por
Licencia Creative Commons
Excepto donde se indique lo contrario, la licencia de este ítem se describe como openAccess